This command causes an analysis to be repeatedly performed while stepping the temperature, a model parameter, a global parameter, or an independent source. Steps may be linear, logarithmic, or specified as a list of values.
Example: .step oct v1 1 20 5
Step independent voltage source V1 from 1 to 20 logarithmically with 5 points per octave.
Example: .step I1 10u 100u 10u
Step independent current source I1 from 10u to 100u in step increments of 10u.
Example: .step param RLOAD LIST 5 10 15
Perform the simulation three times with global parameter Rload being 5, 10 and 15.
Example: .step NPN 2N2222(VAF) 50 100 25
Step NPN model parameter VAF from 50 to 100 in steps of 25.
Example: .step temp -55 125 10
Step the temperature from -55°C to 125°C in 10-degree step. Step sweeps may be nested up to three levels deep.